BL 931700 thumbnail image

BL 931700

pH Mini Controller
with 4-20 mA Recorder Output

Add to Quote Request
BL 931700 image
BL 931700

pH Mini Controller
with 4-20 mA Recorder Output

Product highlights:

  • It's easy to handle
  • Fire retardant casing
  • Selectable overdose protection system
  • Splash resistant cover

Product Description:

The BL 931700 mini pH controller has been designed for easy, affordable installation in tight spaces to perform simple yet effective process control. Thanks to its compact size, the BL 931700 mini pH controller can be installed right next to tanks or vats.

This versatile controller is ideal for a wide variety of applications, such as textiles, papers, photographic solutions, plating baths, chemicals and water treatment.This

BL 931700 is provided with a selectable set point for acid or basic dosage.

Measurements are directly taken from a pH electrode in the range from 0 to 14 with a 0.01 pH resolution. Accuracy is ensured by two point calibration, performed manually through trimmers on the front panel.

Users can choose automatic or manual dosing mode with a switch on the front panel. Manual control is particularly useful during maintenance operations, because it permits operators to enable or disable the dosing relay according to need. The overtime control system advises users when the relay is active for too long, helping to prevent overdosing.

In addition, this model features a 4-20 mA analog output for recorder connection.

Order Information:

BL 931700-0 (12 VDC) and BL 931700-1 ( 115/230V) are supplied with mounting brackets, transparent cover and instruction manual.

Range   0.00 to 14.00 pH
Resolution   0.01 pH
Accuracy @ 25°C   ±0.02 pH
Calibration   manual, 2 point, with offset and slope trimmers
Dosing Relay   max 2A (fuse protected), 250 Vac, 30 Vdc
Dosing Selection   acid or alkaline
contact open=acid dosage=relay ON if measurement > set point contact close=alkaline dosage=relay ON if measurement < set point
Setpoint   adjustable from 0.00 to 14.00 pH
Overtime   adjustable, typically from 5 to approx. 30 minutes
Recorder Output   4-20 mA, accuracy ±0.20 mA, 500 Ohm max load
Input Impedance   102 Ohm
Power Supply   See Chart
Dimensions   79 x 49 x 95 mm (3.1 x 1.9 x 3.7??)
Weight   See Chart
Solutions:
HI 7004L - 4.01 pH Buffer Solution
1 x 500 mL bottle
HI 7007L - 7.01 pH Buffer Solution
1 x 500 mL bottle
HI 7010L - 10.01 pH Buffer Solution
1 x 500 mL bottle
HI 70300L - Electrode Storage Solution
1 x 500 mL bottle
HI 7061L - General Purpose Cleaning Solution
1 x 500 mL bottle
HI 7004L - 4.01 pH Buffer Solution
1 x 500 mL bottle
HI 7007L - 7.01 pH Buffer Solution
1 x 500 mL bottle
HI 7010L - 10.01 pH Buffer Solution
1 x 500 mL bottle
HI 70300L - Electrode Storage Solution
1 x 500 mL bottle
HI 7061L - General Purpose Cleaning Solution
1 x 500 mL bottle
HI 7004L - 4.01 pH Buffer Solution
1 x 500 mL bottle
HI 7007L - 7.01 pH Buffer Solution
1 x 500 mL bottle
HI 7010L - 10.01 pH Buffer Solution
1 x 500 mL bottle
HI 70300L - Electrode Storage Solution
1 x 500 mL bottle
HI 7061L - General Purpose Cleaning Solution
1 x 500 mL bottle
Accessories:
HI 740146 - Mounting Brackets for BL 931700 Housing HI 710005 - Power Adapter, 115 Vac to 12 VDC, US Plug HI 710006 - Power Adapter, 230 Vac to 12 VDC, European Plug HI 740146 - Mounting Brackets for BL 931700 Housing HI 710005 - Power Adapter, 115 Vac to 12 VDC, US Plug HI 710006 - Power Adapter, 230 Vac to 12 VDC, European Plug HI 740146 - Mounting Brackets for BL 931700 Housing HI 710005 - Power Adapter, 115 Vac to 12 VDC, US Plug HI 710006 - Power Adapter, 230 Vac to 12 VDC, European Plug
Probes:
HI 1001 - Flow-thru Monitoring pH Electrode with BNC Connection and 3 m Cable HI 1001 - Flow-thru Monitoring pH Electrode with BNC Connection and 3 m Cable HI 1001 - Flow-thru Monitoring pH Electrode with BNC Connection and 3 m Cable
Manual:
MANBL_931700